{"id":"EM-20261103-JA5H","url":"https://cyber.eventmonitor.net/incident/EM-20261103-JA5H/","type":"cve","title":"Vulnerability (CVE-2026-58115)","subtitle":"CVE-2026-58115","subject":"CVE-2026-58115","status":"Confirmed","severity":"medium","affected":[],"headline":"4 hours from first report to confirmed exploitation.","born":"2026-11-03T09:42:06.626Z","firstSignal":"2026-11-03T05:34:41.000Z","lastSignal":"2026-11-03T09:42:06.626Z","updated":"2026-11-04T09:24:33.782Z","revision":2,"life":[{"status":"Born","at":"2026-11-03T09:42:06.626Z","why":"second independent source: C56 AlienVault OTX pulses"},{"status":"Developing","at":"2026-11-03T09:42:06.626Z","why":"signals keep joining"},{"status":"Confirmed","at":"2026-11-03T09:42:06.626Z","why":"exploitation in the wild reported"}],"changeLog":[{"at":"2026-11-03T05:34:41.000Z","what":"First signal: C130 The Hacker News"},{"at":"2026-11-03T09:42:06.626Z","what":"Born: second source, C56 AlienVault OTX pulses. Page EM-20261103-JA5H created."},{"at":"2026-11-03T09:42:06.626Z","what":"Status: Confirmed (exploitation in the wild reported)"}],"stages":[{"name":"Disclosed","at":"2026-11-03T05:34:41.000Z","detail":"C130 first to name it"},{"name":"Scored","at":"2026-11-03T05:34:41.000Z","detail":"No CVSS yet · EPSS 0.9%"},{"name":"Exploited","at":"2026-11-03T09:42:06.626Z","detail":"C130 reports use in the wild"},{"name":"Advisories","at":null,"detail":"None yet"},{"name":"Vendor Response","at":null,"detail":"None in sources yet"},{"name":"Resolved","at":null,"detail":"After 14 quiet days"}],"signals":[{"at":"2026-11-03T05:34:41.000Z","source":"C130","sourceName":"The Hacker News","role":"Research & News","severity":2,"title":"Attacker  Exploit Critical Siemen  IoT2050 Flaw to Plant Remote Command Backdoor","text":"A maximum-severity security flaw impacting Siemens SIMATIC IoT2050 Advanced devices has come under active exploitation, VulnCheck has revealed. The vulnerability, tracked as CVE-2026-58115 (CVSS score: 10.0), is a case of missing authentication for a critical function that could be exploited by an unauthenticated remote attacker to run arbitrary code. \"SIMATIC IoT2050 Advanced devices running","url":"https://thehackernews.com/2026/11/attackers-exploit-critical-siemens.html"},{"at":"2026-11-03T09:42:06.626Z","source":"C56","sourceName":"AlienVault OTX pulses","role":"Research & News","severity":2,"title":"Exploitation Targeting Node-RED, a Tool Embedded in ICS Product","text":"On October 30, 2026, exploitation activity was detected targeting CVE-2026-58115, an unauthenticated Node-RED admin API vulnerability. Attackers deployed malicious flows that automatically download and execute Linux bots through three layers of encoding. The exploit originated from IP 4.201.105.116 ","url":"https://otx.alienvault.com/pulse/6ae9ac6e66c89c6be4d99928"}],"crowd":[],"reference":{"nvd":null,"kev":null,"epss":{"epss":0.0089,"pct":0.59407,"at":1793784273782},"p0":false},"mergedInto":null,"publisher":"Event Monitor Cyber"}