Event Monitor Cyber
EM-20261112-4Q19 OutageHigh severity

Google: Network Connectivity Drop

Nov 12, 2026 · Provider · reported by IODA (Georgia Tech), Provider status pages (Statuspage)

Share
Status
Confirmed

Since : 1 provider status page acknowledged it.

First Signal
Nov 12 10:25 UTCC111 IODA (Georgia Tech)
Page Born
Nov 12 16:43 UTCsecond source joined
Last Signal
Nov 12 18:00 UTC3 hours before snapshot
Sources
21 official · 1 research, news or crowd
Lasted
9 hoursso far

Life Of This Page

  1. 1
    Born
    A second, independent provider or measurement sees it.
  2. 2
    Developing
    Reports and measurements join.
  3. 3
    Confirmed · Now
    A provider status page acknowledges it.
  4. 4
    Resolved
    Not yet
    Every provider marks it resolved and 6 hours pass quietly, or 24 hours pass with no new signal.
  5. 5
    Archived
    Not yet
    30 days after resolved. Read only; the link keeps working. Reopens if it comes back.

The ID never changes, and earlier addresses keep working. A correction is logged, never overwritten. If two pages turn out to be one incident, the later one points to the earlier.

Outage Lifecycle

  1. First Report: reached
    Nov 12 10:25 UTC
    C111 IODA (Georgia Tech)
  2. Corroborated: reached
    Nov 12 16:43 UTC
    2 independent sources
  3. Acknowledged: reached
    Nov 12 16:43 UTC
    C123 status page
  4. Network Check: not yet
    Not yet
    No network data for this provider
  5. Restored: not yet
    Not yet
    Still open

Timeline

06:0012:0018:00Nov 13BornC111 IODA (Georgia Tech)C123 Provider status pages (Statuspa

Point at a mark to read it. Squares are signals, colored by severity; every one is also listed under Signals.

Signals

  1. Connectivity drop: AS43515 (YOUTUBE) (Google Ireland Limited) (opens source in a new tab) 1 IODA alerts in 6 hours (1 critical), signals: bgp. Entity type: asn. Med severityMeasurementC111 IODA (Georgia Tech)
  2. Firebase: Firebase Hosting is experiencing slightly elevated 502 errors on requests for dynamic content (opens source in a new tab) Requests for dynamic content from Firebase Hosting (rewrites to Cloud Run & Functions, POST requests to Firebase Auth) are experiencing slightly elevated rates of 502 errors. High severityProvider StatusC123 Provider status pages (Statuspage)
  3. Connectivity drop: AS36383 (GEN-AS1) (Google LLC) (opens source in a new tab) 1 IODA alerts in 6 hours (0 critical), signals: bgp. Entity type: asn. Med severityMeasurementC111 IODA (Georgia Tech)