{"id":"EM-20261114-BRXP","url":"https://cyber.eventmonitor.net/incident/EM-20261114-BRXP/tenda-ac18-vulnerability-cve-2026-129258/","type":"cve","title":"Tenda AC18 Vulnerability (CVE-2026-129258)","subtitle":"CVE-2026-129258","subject":"CVE-2026-129258","status":"Developing","severity":"high","affected":[],"headline":null,"born":"2026-11-14T15:31:45.000Z","firstSignal":"2026-11-14T15:16:58.257Z","lastSignal":"2026-11-14T15:31:45.000Z","updated":"2026-11-14T16:30:42.238Z","revision":1,"life":[{"status":"Born","at":"2026-11-14T15:31:45.000Z","why":"second independent source: C29 CIRCL Vulnerability-Lookup"},{"status":"Developing","at":"2026-11-14T15:31:45.000Z","why":"signals keep joining"}],"changeLog":[{"at":"2026-11-14T15:16:58.257Z","what":"First signal: C6 NVD CVE API 2.0"},{"at":"2026-11-14T15:31:45.000Z","what":"Born: second source, C29 CIRCL Vulnerability-Lookup. Page EM-20261114-BRXP created."}],"stages":[{"name":"Disclosed","at":"2026-11-14T15:16:58.257Z","detail":"C6 NVD published"},{"name":"Scored","at":"2026-11-14T15:16:58.257Z","detail":"CVSS 8.5"},{"name":"Exploited","at":null,"detail":"No exploitation reported"},{"name":"Advisories","at":null,"detail":"None yet"},{"name":"Vendor Response","at":null,"detail":"None in sources yet"},{"name":"Resolved","at":null,"detail":"After 14 quiet days"}],"signals":[{"at":"2026-11-14T15:16:58.257Z","source":"C6","sourceName":"NVD CVE API 2.0","role":"Database","severity":3,"title":"CVE-2026-129258 (CVSS 8.5)","text":"A vulnerability was identified in Tenda AC18 15.03.05.05_multi/15.03.05.19 Build 6318. Affected by this vulnerability is an unknown functionality of the file /cgi-bin/upgrade of the component Firmware Upgrade Handler. Such manipulation of the argument upgradeFile leads to insufficient verification of data authenticity. The attack may be launched remotely. The exploit is publicly available and might be used.","url":"https://nvd.nist.gov/vuln/detail/CVE-2026-129258"},{"at":"2026-11-14T15:31:45.000Z","source":"C29","sourceName":"CIRCL Vulnerability-Lookup","role":"Database","severity":2,"title":"GHSA-wxr2-fxvm-rgwm / CVE-2026-129258","text":"A vulnerability was identified in Tenda AC18 15.03.05.05_multi/15.03.05.19 Build 6318. Affected by this vulnerability is an unknown functionality of the file /cgi-bin/upgrade of the component Firmware Upgrade Handler. Such manipulation of the argument upgradeFile leads to insufficient verification…","url":"https://vulnerability.circl.lu/vuln/GHSA-wxr2-fxvm-rgwm"}],"crowd":[],"reference":{"nvd":{"published":"2026-11-14T15:16:58.257","score":8.5,"severity":"HIGH","desc":"A vulnerability was identified in Tenda AC18 15.03.05.05_multi/15.03.05.19 Build 6318. Affected by this vulnerability is an unknown functionality of the file /cgi-bin/upgrade of the component Firmware Upgrade Handler. Such manipulation of the argument upgradeFile leads to insufficient verification…","product":"","seen":1794673842238},"kev":null,"epss":null,"p0":false},"mergedInto":null,"publisher":"Event Monitor Cyber"}