{"id":"EM-20261118-5TLF","url":"https://cyber.eventmonitor.net/incident/EM-20261118-5TLF/philips-hue-bridge-homekit-accessory-protocol-vulnerability-cve-2026-126979/","type":"cve","title":"Philips Hue Bridge HomeKit Accessory Protocol Vulnerability (CVE-2026-126979)","subtitle":"CVE-2026-126979","subject":"CVE-2026-126979","status":"Developing","severity":"high","affected":[],"headline":null,"born":"2026-11-18T00:18:38.590Z","firstSignal":"2026-11-13T06:00:00.000Z","lastSignal":"2026-11-18T00:18:38.590Z","updated":"2026-11-18T01:11:27.889Z","revision":1,"life":[{"status":"Born","at":"2026-11-18T00:18:38.590Z","why":"second independent source: C6 NVD CVE API 2.0"},{"status":"Developing","at":"2026-11-18T00:18:38.590Z","why":"signals keep joining"}],"changeLog":[{"at":"2026-11-13T06:00:00.000Z","what":"First signal: C37 Zero Day Initiative (published)"},{"at":"2026-11-18T00:18:38.590Z","what":"Born: second source, C6 NVD CVE API 2.0. Page EM-20261118-5TLF created."},{"at":"2026-11-18T00:18:38.590Z","what":"Severity raised to High by C6"}],"stages":[{"name":"Disclosed","at":"2026-11-18T00:18:38.590Z","detail":"C6 NVD published"},{"name":"Scored","at":"2026-11-18T00:18:38.590Z","detail":"CVSS 8.8"},{"name":"Exploited","at":null,"detail":"No exploitation reported"},{"name":"Advisories","at":null,"detail":"None yet"},{"name":"Vendor Response","at":null,"detail":"None in sources yet"},{"name":"Resolved","at":null,"detail":"After 14 quiet days"}],"signals":[{"at":"2026-11-13T06:00:00.000Z","source":"C37","sourceName":"Zero Day Initiative (published)","role":"Research & News","severity":2,"title":"ZDI-26-964: (Pwn2Own) Philips Hue Bridge HomeKit Accessory Protocol chacha20_decrypt Integer Underflow Remote Code Execution Vulnerability","text":"This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability. The ZDI has assigned a CVSS rating of 8.8. The following CVEs are assigned: CVE-2026-126979.","url":"http://www.zerodayinitiative.com/advisories/ZDI-26-964/"},{"at":"2026-11-18T00:18:38.590Z","source":"C6","sourceName":"NVD CVE API 2.0","role":"Database","severity":3,"title":"CVE-2026-126979 (CVSS 8.8)","text":"Philips Hue Bridge HomeKit Accessory Protocol chacha20_decrypt Integer Underflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the HomeKit Accessory Protocol service, which listens on TCP port 8080 by default. When parsing pairing requests, the process does not properly validate user-supplied data, which can result in an integer underflow before writing to memory. An attacker can…","url":"https://nvd.nist.gov/vuln/detail/CVE-2026-126979"}],"crowd":[],"reference":{"nvd":{"published":"2026-11-18T00:18:38.590","score":8.8,"severity":"HIGH","desc":"Philips Hue Bridge HomeKit Accessory Protocol chacha20_decrypt Integer Underflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Authentication is not required to exploit this…","product":"","seen":1794964287889},"kev":null,"epss":null,"p0":false},"mergedInto":null,"publisher":"Event Monitor Cyber"}